Time Remaining For Same Day Dispatch -
Time Remaining For Same Day Dispatch -
Product Ref: WO3600
7 people have viewed this product in the last 24 hours
In stock
Out of stock
No rating yet
Thank you. Your review has been submitted and subject to moderation, will appear on this page shortly.
0 loyalty points
ISF Euro Fire FR Isolator is a two pack water based clear wood, timber & furniture grade class 0 Flame Retardant Intumescent isolator for natural hard wood, MDF & veneered MDF.
Ideal use for when working with timber that will rest in moist conditions or with exotic species timbers that may seep oils and sap.
It provides a finish which both protects the wood & highlights its natural beauty. It enables the designer to maintain the overall decorative effect required whilst complying with today’s building regulations for fire protection.
Mix ratio is 10:1 with the EuroFire FR Catalyst.
This 2-pack PU acrylic system is easy to apply with any type of spray equipment. It provides good flow and excellent film clarity, can be colour-matched to pretty much any colour and has excellent anti-yellowing properties. EF1 also has good resistance to abrasion and scratching and meets FIRA 6250 Severe Use rating.
The coating system is straightforward.
1) To upgrade standard timber to Euro Class B-s1d0, apply two layers of basecoat followed by a clear or coloured topcoat.
2) Basecoats can be thinned by up to 10% using Euro-Fire EFT thinner, and the topcoat can be applied to the correct thickness in thin layers.
3) If you're working with timber in atmospheric conditions, exotic timbers or pre-treated fumed timber, use an isolator coating before applying the basecoat.
This improves adhesion and stops the wood from having a milky-looking finish. So, for example, you would need an isolator coating in a hotel with a timber-clad spa as it would be subject to moisture and humidity.
1)Maintaining cladding to Euro Class B fire retardancy is easy. Just apply one basecoat layer and one topcoat layer.
Remember: Fire protection coatings only work when applied to the correct thickness. Isolators, basecoats, and topcoats have different coverage requirements to be compliant, so always double-check the technical datasheet before using a product.
In the wake of the Grenfell Tragedy the givernment has firmed up its classfications formerly known as Class 0 to include further controls for the fire safety and ignition of timbers in buildings.
If you are installing, spraying or modofying timbers in any residential or commercial setting you'll now need to ensure your paint system complies to Part B of the Building regulations and Fire Regulations code.
The new Class B system is a beefed up version of Class 0 with a major difference. Class 0 was a standalone rating where a classification was given such as NA, 1-4 or Unclassified. The new Class B follows the Euro system and takes into account 2 overlapping ratings.
Firstly you have letters A-F which correspond to the old class system so a Euro B is the old Class 0 (see table below). However to further bolster the safety of the rating there is an overlapping rating that meets with the letter classficiation. So a product may now be a Euro B s2 d0. The Euro B is the new Class 0 standard and the S stands for level 2 for Smoke Development while the d0 is the realtive droplets falling from the flame.
s2 is the amount of smoke generated, 1 would be best, 3 the worst
d0 is the relative amount of flaming particles falling , 0 is best, 2 the worst
(see the table below for best to worst ratings for the additional tests.
British Standard Classification | European Standard Classification |
Not Applicable | A |
0 | B |
1 & 2 | C |
3 | D |
4 | E |
Unclassifiable | F |
Products with a European rating have other lower case letters and numbers written after the letter – Do they mean anything?
Yes they do. Let’s say you have C-s2,d0
C is the resistance to fire (as shown in the earlier chart)
s2 is the amount of smoke generated, 1 would be best, 3 the worst
d0 is the relative amount of flaming particles falling , 0 is best, 2 the worst
Additional classes for smoke development | Additional classes for burning droplets |
s1 the structural element may emit a very limited amount of combustion gases | d0 burning droplets or particles must not be emitted from the structural element |
s2 the structural element may emit a limited amount of combustion gases | d1 burning droplets or particles may be released in limited quantities |
s3 no requirement for restricted production of combustion gases | d2 no requirement for restriction of burning droplets and particles |
If you are spraying timbers you need to know not only the classification but also what classification to stick to for each job you take on!
OK, so what do Building Regulations say I need?
That depends on where exactly you will use the wallcovering. The chart included here shows how different rated wallcoverings can be used in projects subject to Building Regulations:
Location | Old BS Class | New European Class |
Small rooms of an area not more than: | 2 | D-s3,d2 |
Other rooms (including garages) | 1 | C-s3,d2 |
Circulation spaces in dwellings | 1 | C-s3,d2 |
Other circulation spaces, including the common areas in blocks of flats | 0 | B-s3,d2 |
Specification
Brand | ISF |
Application | Brush, Roller, Spray |
Overcoating Time | 3 Hours |
Coverage m² P/Litre | 8 |
Mix Ratio | 1:1 |
Pot Life | 5 Hours |
Recommended Cleaner | Water |
Published: April 20, 2018
Published: June 29, 2020
Published: July 2, 2021
Published: November 9, 2021
Published: April 12, 2023
Published: April 19, 2023
Published: July 27, 2023
Published: October 24, 2023
The below products are often purchased together with the above item.